When we took possession of Eolian, the PVC and rubber head hoses had been permeated by the 'contents' of those hoses, making a bad smell everywhere down below. We replaced all of those hoses early on with good hose. In 2006, about 7 years later, those hoses had again been penetrated. My research (oh sure, NOW do the research...) showed that even the highest grade hose (which costs in excess of $10/ft) permeates in 10 years. The cheaper grades are supposed to last only 5 years. I guess that means that we did better than most.
The same research showed that solid PVC pipe (like that used in houses) will NEVER permeate. So, OK - out with the hose, and in with solid PVC pipe. First problem: most plumbing supply houses stock only ABS for sanitary fittings (long sweep elbows, sanitary tees, etc... Things can get hung up in regular sharp-cornered elbows, and sewer snakes can't be made to go around sharp corners.) But we have found a couple of stores close by that stock PVC fittings, and in ALL the weird angles we will need to use to run pipe in a boat. Also, some short lengths of hose are still needed to make connections at the ends of the pipe runs - stuff moves on a boat, and flexible connections are required to prevent breaking the pipe, so special hose-to-pipe adapters were needed. Found those too, in a store that specializes in marine heads.
The first of many batches of about $60 worth of fittings:
I have found that it takes way more fittings to do this plumbing on a boat than it does to plumb a house. In a house, virtually everything can be addressed with 90 degree elbows - 45s are rarely used. On a boat it is the 90 which is rare.
So I make up a part of a run, studying the various combinations of fittings needed to make the corners and still trying to fit the triple criteria of:
- Use the minimum number of fittings because they cost a lot
- Make things neat - fit the piping into the available space tightly
- Make corners gradual - two 45s with a short length of pipe are better than a long sweep 90
Also, there is the logistics of assembly. Put things together in the wrong order, and you literally "can't get there from here". Finally, the small spaces get you. For example, the inside dimension of the forward head sink vanity, thru which two runs needed to pass, is 27". Outside dimension, and leaving enough to cement on a fitting on the end, is 31". But because of the cramped spaces, there is no way to get a 31" piece of pipe in there. So, you cut it in half, and join it with a coupling inside the cabinet. Standing on your head. Working at arm's length in a small space. Breathing in the PVC cement fumes.
Also, because I can, I included cleanouts (wyes with screw-out plugs) where it made sense (at least one on each pipe run). These allow access with a sewer snake, but also provide a port which can be used to add hydrochloric acid to dissolve the carbonates which form as a reaction product between urine and seawater. I decided that all these cleanouts need to be above the waterline, so the plugs can be safely removed even if the seacocks are not closed.
Finally, I used PVC fittings to make improved versions of the vented loops. The original bronze ones were only 1" internal diameter, and were mostly clogged with carbonates anyway. Mine are 1.5" diameter all the way thru, and in addition provide a disengaging zone below the vent line so that it is less likely that sewage will enter that vent line. (Vented loops are required because the heads would directly communicate with the sea when the overboard discharge line is open - and the heads are located below the waterline. Without the vented loop, a siphon could start, with the ocean filling the boat thru the head. The vented loop is a siphon breaker.)
Oh and by the way, I discovered while cutting pipe on the dock, that PVC pipe doesn't float. Just sayin'
3 comments:
Hey Bob,
this head re-plumbing post would make a great compliment to the holding tank replacement article that we have on the site from you already. :)
Just saying!
Scott
Bob,
Great blog. I am especially enjoying the project posts. I would also like to replace my head hoses with PVC. Can you give me the name of your source for the PVC to Hose adapters? That has been my hangup until now. Did you fit an adapter at the head and the thru-hull, or is it PVC right up to the thru-hull?
Thanks,
Chris
Hi Chris -
Thanks!
Indeed, the hose to pipe adapters were the hardest part to source. I got my adapters from a local head shop (OK, bad pun) here in Seattle: Marine Sanitation. If you are from Seattle, they are next door to Fisheries Supply in Mariner's Square.
I used hose at both ends of all the pipe, because I wanted to isolate the pipe from vibration, etc. So, answering your question directly: Yes, I used short lengths of hose at the head and at the thru hull.
bob